INSTALLATION
REMOTE CONTROL
Use the Hampton
®
Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very important).
Run wires from the fi replace to that location,
use Thermostat Wire Table.
WALL THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH" on
the gas valve. Use table below to determine the
maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Hampton
®
offers an optional programmable thermo-
stat but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.
Thermostat Wire Table
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
For
PROPANE
Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.