Installation, Venting arrangements, Rotating 45 – Regency Hampton H35 Large Gas Stove User Manual
Page 16: Elbow for straight horizontal terminations

16
Hampton® H35-2 Direct Vent Freestanding Gas Stove
INSTALLATION
Offset to Vertical Terminations
VENTING ARRANGEMENTS
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical and
offset to vertical runs with vertical terminations. Maximum two 45
o
elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs with
horizontal terminations. Maximum one 90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
All approved caps listed on page 12 - may
be used.
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The venting arrangements diagrammed below,
have a min. of 75% (fl ue loss) effi ciency with Fan
Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
ROTATING 45
O
ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS
1) Remove all 4 screws that secure
the elbow to the unit using a 1/4"
magnetic nut driver.
2) Rotate the elbow 180
o
3) Secure the elbow by securing
it with the 4 screws.
Remove all 4 screws
and washers
NOTE: See "Vent Restrictor Position" section for
installation instructions for the Vent Restrictor
Position.