INSTALLATION

31) Locate the ground lug at the receptical

box, left of the unit.

32) Connect one end of the supplied green

ground wire to the lug with the nut and
washer from the kit.

33) Install the 1/2" bushing to the heat shield.

Ground

wire from

kit

35) Plug the DC spark generator wires to the

DC Sparker.

36) Connect the ground wire to the DC

Sparker mounting bracket.

38) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which is
provided in the kit.

40) Tie up the loose wire with the wire clip.

Heat Shield

34) Run the other end of the ground wire and

DC spark generator wires through the
bushing on the heat shield.

39) Find a location which is not too hot and is

easy to reach for changing the

battery.

Installer Notice:

These instructions must be left

with the appliance.

41) Check for gas leaks with a proper soapy

solution or leak detector.

42) Check for proper spark between the

ignitor and pilot cap. Refer to "Lighting
Procedure" section of the manual for light-
ing sequence.

43) Check pilot fl ames. Correct fl ame pattern

has 3 strong blue fl ames. Adjustment can
be made by turning the slotted screw at
the top right corner of the valve. Refer to
"Maintenance Instructions" section of the
manual for correct fl ame patterns.

44) Check inlet (12" WC min) and outlet (11"

WC) pressures. Refer to "Gas Pipe Pres-
sure Testing" section of the manual.

45) Check operation of fl ame control.

46) Check for proper fl ame appearance and

glow on logs.

37) Install the supplied battery into the DC Sparker