INSTALLATION

INSTALLATION

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label), after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.

LOCATING YOUR

GAS FIREPLACE

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

Diagram 1

1) When selecting a location for your fi replace,

ensure that the clearances are met.

2) The appliance must be installed on a fl at,

solid, continuous surface For example a
wood, metal or concrete fl oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.

3) The B41XT Gas Fireplace can be installed

in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your Gas

fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantle Clearances (Refer to "Combustible

Mantel Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top Standoffs and Top Facing

Support and Side Nailing Strips (Refer to "Unit
Assembly Prior to Installation" Section).

Note:

Must be done before installing unit into place.

3) Install vent (Refer to "Venting" sections).

4) Install 1-AA battery into the DC Sparker.

Note: Pilot cannot be lit without battery in place.

5) Make gas connections. Test the pilot. Must be

as per diagram (Refer to "Pilot Adjustment"
section).

6) Make electrical connections to receptacle

supplied with unit (recommended).

7) Install standard and optional features. Refer

to the following sections:


a. Inner Panels or Brick Panels (Required)

b. Log Set Installation

c. Standard Flush Door

d. Remote Control (Optional)

e. Wall Switch

f. Wall Thermostat (Optional)

g. Fan Installation (Optional)

h. Light Installation (Optional)

i. Louvers / Flush Panels

j. Full Screen Arch Door

k. Finishing Trim (Optional)

8) Final check.

4) This appliance is Listed for bedroom

installations using the standard Remote
(millivolt thermostat system). Some areas may
have further requirements, check local codes
before installation.

5) The B41XT Gas Fireplace are approved for

alcove installations, see "Clearances" section
for details.

6) We recommend that you plan your installation

on paper using exact measurements for
clearances and fl oor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.

Note: For vent terminations refer to "Exterior

Vent Termination Locations" section.