beautypg.com

Maintenance, Accent light bulb replacement – Regency Bellavista B41XTE Large Gas Fireplace User Manual

Page 58

background image

58

Regency Bellavista™ B41XT Gas Fireplace

MAINTENANCE

1) Shut off electrical supply.

2)
Remove Full Screen Door and bottom Louver if installed.

3) Remove the glass door - see instructions in manual.

4) Remove the logs, lava rock and vermiculite if installed.

5) Remove the brick or inner panels if installed - see instructions in manual.

6) Remove the burner and rear log tray - see below.

Diagram 1: Remove the left and right screws.

Diagram 2: Slide burner assembly to the right

and then remove.

8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3

Diagram 3

7) Slide the burner assembly to the right to release it from the orifi ce,

then lift it out.

9) Remove the 2 screws securing the base tray - lift base tray up and

out. Diagram 4a and 4b.

Diagram 4a

Diagram 4b

10) Replace the bulbs as necessary.

Note: Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.

11) Reverse steps 9 - 1.

Base Tray

ACCENT LIGHT BULB REPLACEMENT