20. TROUBLESHOOTING GUIDE - 120v THERMOSTAT

SET THERMOSTAT TO CALL FOR HEAT

COMBUSTION AIR BLOWER STARTS

NO

YES

NO

CHECK WIRING CONNECTION, FUSE / CIRCUIT
BREAKER.

AIR PROVING SWITCH CLOSED
110 VOLTS AT IGNITION CONTROL

NO

ENSURE THAT THE AIR INTAKE AND FLUE

ARE NOT BLOCKED

ENSURE PRESSURE TUBE IS CONNECTED AND

NOT BLOCKED

CHECK AIR PRESSURE WITH MANOMETER
CHECK AIR PROVING SWITCH IS CLOSING

WHEN BLOWER IS RUNNING

REPLACE DEFECTIVE SWITCHES

SPARK ACROSS IGNITER OR
IGNITER/SENSOR GAP

NO

SEE SPARK IGNITION CIRCUIT (on Page 24)
PULL IGNITION LEAD AND CHECK SPARK
CHECK SPARK GAP, ADJUST TO 1/8” TO 3/16” IF

NEEDED USING THE GROUND PRONG ONLY

SPARK OK?

REPLACE IGNITION CONTROL

CHECK IGNITION CABLE, GROUND WIRING

CERAMIC INSULATOR AND CAP.

CHECK BOOT OF THE IGNITION CABLE FOR

SIGNS OF MELTING OR BUCKLING.

TAKE PROTECTIVE ACTION TO SHIELD CABLE

AND BOOT FROM EXCESSIVE TEMPERATURES.

NO VOLTAGE AT PIN 4 - CHECK THERMOSTAT

CHECK FOR LINE VOLTAGE POWER SUPPLY.
CHECK FOR VOLTAGE AT BLOWER MOTOR
IF VOLTAGE IS PRESENT, REPLACE MOTOR.