beautypg.com

S&S Cycle VFI Module and Pro Tune II Software User Manual

Page 11

background image

11

The communications status box shows the ECU model number (55-5029A in the example above) and the ECU software version (C281 in the
example above). The box to the left also shows the serial number of the ECU (00023791 in the example above). This information may be required
for customer support.

If you do not have a serial port on your computer, you may use a USB-Serial adapter instead. We recommend the Belkin® F5U109 USB-Serial adapter
as the Pro Tune II Software has been extensively tested with this unit.

If you cannot establish a connection with your ECU:
Please consult the complete Pro Tune II manual. A shortcut to the manual was installed on your desktop during the ProTune II installation. It can also
be found on the installation CD or in the Technical section of the www.sscycle.com website.

ATTENTION: Included on this installation CD is a desktop shortcut to our complete Pro Tune II Manual. Please print it out and keep it with
you as you work with the software. A link to the manual can also be found in the Technical section of our website at www.sscycle.com.

The module must be loaded with a calibration file from the included CD-ROM or from the sscycle.com website in order to operate.

You should only attempt to load calibration files that have been directly supplied by S&S® Cycle. Attempting to upload other files may
leave your ECU in an unusable state.

J. Sending Box File Data to an ECU

Calibration (File) - A complete copy of all the configuration data inside an ECU, stored as a file on disk. There are two types of Calibrations files,
tune-files and BOX files.

BOX File - A type of calibration file that contains a complete record of the ECU configuration data (a tune-file) paired with an ECU software
program file (a .h86 file). S&S Cycle BOX files have a .box file extension.

Tune-File - A type of calibration file which only contains the ECU configuration data. Use of Tune-Files is for backward compatibility only. S&S
Cycle Tune-Files have a .ecc file extension.
1. Make sure the ECU is connected (the bottom right corner of the screen should be green and list the ECU part number and software level).
2. Go to the File menu and select Send All Data to ECU or select the Send All Data to ECU button on the tool-bar. A box will appear which

enables you to select a Box File for Pro Tune II to load into the ECU.

3. Find an appropriate file, click on it, then click Open and the program will start to transfer the data to the ECU.
4. If an error occurs during the transfer you may need to repeat the process.

K. Special Notes about Operation

The Stepper Motor Orientation Setting allows for different orientation of stepper motor wiring. The orientation should be left as default unless
you have reason to alter it. The correct orientation is such that an increase in stepper number corresponds to an increase in throttle. More
information about this can be found in the Advanced section of the Pro Tune II Manual.
1. Select the Stepper Motor Orientation Setting in the View menu.
2. The Select Data Source dialog box will appear. The dialog box will list the current active data sources, i.e. ECU if it is connected, the

demonstration calibration file built into the software and any calibration files that you accessed since starting the software. To select a data
source, click on it to highlight it and then click OK or press Enter. You can also double-click on an item to select it. If you want to browse for
another calibration file, select the 'A calibration file not on this list' option. This will cause an Open File dialog box to appear. Select a
calibration file from this dialog box and click Open.

WARNING