Specifications, Using an entry confirm button – Paxton Long range reader User Manual
Page 6

11V DC
14V DC
1 A
11V DC
14V DC
80 mA
119 kHz
140 kHz
2.405 GHz
2.480 GHz
600 µs
Belden 9540
100 m
0.75 mm sq
2.5 mm sq
80 mm
40 mm
10 mm
5000 mm
2000 mm
P200
2500 mm
P75
1500 mm
P50
1100 mm
P38
850 mm
- 35 °C
+ 66 °C
IP66
220 mm
220 mm
135 mm
Specifications
Voltage - Reader module
Clock and data bit period
Carrier frequency
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current - Reader module
P200E metal mount
Cable type for extensions
Cable length between ACU and reader
Read range with hands free token
Waterproof
Additional power supply required
Outdoor use
Button confirmation input
Yes
Yes
Long range reader
Min
Min
Max
Max
Paxton Access Ltd hereby declares that this product is in conformity with all the essential requirements of Directive 1999/5/EC.
This equipment is intended for use in all EU and EFTA countries and all other countries worldwide.
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
Token
Keyfob
Watchprox
Read range with passive tokens
Long range reader
Using an entry confirm button
Where more than one door interface can pick up the hands free token, a 'push to make' button can be used
to select the required door. Where fitted, the LED on a confirm button will flash for 5 seconds after the
hands free token has been recognised and must be pressed to unlock the door.
Once an entry confirm button has been fitted to the interface PCB, perform the following sequence:
1. Power down the interface board.
2. Power up the interface board.
3. Press and hold the entry confirm button for a minumum of 3 seconds within 60 seconds of power up.
To disable the use of the button, repeat the above sequence.
Voltage - Interface module
Current - Interface module
12V Power cable core diameter - up to 5 m run
12V Power cable core diameter - up to 100 m run