Page 8
-20 °C
+55 °C
IPX7
10V DC
14V DC
165 mA
215 mA
125 kHz
600 µs
68 mm
109 mm
22 mm
40 mm
30 mm
400 mm
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
DC supply voltage
Carrier frequency
Specifications
Operating temperatures - all items
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
DC supply current
Cable length
Read Range
Token
Keyfob
Hands free token
Waterproof
PROXIMITY LCD reader
Reader mounting plate
Documentation
Fixing Kit - LCD reader
fk1-087
4
No 6 x
3
/
4
in pozi pan self tapping screw - zinc
4
22 mm Wall Plugs
5
Cable clips
1
LCD reader removal tool
Contents in box
Description
Option
Qty
Min
Max
This product is not suitable for retail sale. All warranties are invalid if this product is not installed by a competent person.
5 metres
Clock and data bit period
Silent operation feature
Yes
Outdoor use
Factory reset
The reader can be reset to a factory default state by carrying out the following operation:-
1.
Connect together the yellow and green wires. (reset link)
2.
Connect power to the reader.
3.
The reader will beep 3 times to confirm the reset sequence.
4.
Remove the power and remove the reset link.
This factory reset sequence results in the LCD reader images returning to the default images, the LCD reader
name will be cleared and the reader password will be blanked.