Technical help, Specifications – Paxton Vandal resistant compact metal keypad User Manual
Page 4
![background image](/manuals/570087/4/background.png)
1
50
9V
24V
9V
12V
150 mA
1 A
1 A
24V
2 A
1 A
-20 °C
+55 °C
IPX7
89 mm
143 mm
28 mm
89 mm
143 mm
40 mm
Voltage AC
Dedicated lock output current
Specifications
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current
Outdoor use
Features
Number of Codes
Code length
Door open time
Silent operation
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Exit button input
Door Contact input
Alarm/bell output voltage
Waterproof
Backlight
Cable length
Min
Max
Min
Max
Yes
Yes
Yes
Yes
No
3 metres
Here is the list of topics about this product that receive the most technical support enquiries.
We list them here to help you speed up the installation and trouble shooting process.
Technical Help
Yes
1 - Can I use a fail open release (e.g. Maglock)?
Q
By default, the compact keypad is set to operate with a fail locked release by providing a voltage across the lock wire pair when
Q
a valid entry is made. To use a fail open release, the lock wire setting needs to be changed (Program option 1).
2 - How do I integrate an entry phone system?
Q
The output from the entry phone system is used to simulate the 'push' of an exit button for the Paxton equipment. No voltage
Q
should be directly applied to the exit wires (Blue / Mauve).
Q
Most phone systems provide a powered output pair to drive the door lock. This voltage must be used to drive an independent
Q
relay. The relay contacts must be 'normally open going closed' to mimic a 'push to make' exit button. The voltage free relay
Q
can then be connected directly across the exit wires.
3 - What are the keypad code types used for?
Q
Normal - Releases the door for the time period set in Option 5.
Q
Toggle - Releases the lock until the code is entered for a second time.
Q
Duress - Releases the lock (as in Normal) but also energizes the bell output for 30 seconds.
Q
Delete - Used to remove a specific code that has already been entered in Multiple mode.
4 - Can I connect a compact with another Paxton control unit?
Q
This cannot be done. Paxton Compact systems have the control electronics built in and no direct data output is provided.
Q
The Switch2 and Net2 system use a different type of data input.
Q
Note: The compact system is designed to control the door unit on its own.
5- Can I have read in and read out on one door with two keypad units?
Q
You cannot wire the lock outputs from two units in parallel to a common lock as they will both power the door lock
Q
independently and will not offer single point control. The power supply or keypads may also be damaged.
Q
We therefore recommend using an independent power feed switched through the relay outputs (COM/N.O./N.C.) of the two
Q
units to provide the lock control required.
Relay switchable voltage
Relay switchable current
Dedicated lock output voltage
Alarm/bell output current
With mounting plate
With surface mount box
Maximum load output current
Follows supply voltage
Follows supply voltage
Lock + bell
Voltage DC
60 secs
1 sec
4 digits
8 digits