NOTE: The fiber optic ports work in Full-Duplex mode in both Auto and Manual negotiation modes.

3.2.1.2

SW3, SW4, SW5 - Reserved

These DIP-switches are for factory use only and must always remain in the Left/Down position (factory
default).

3.2.1.3

SW6, SW7, SW8 - Link Modes

These three DIP-switches configure the link mode settings. The following table details possible Link Mode
DIP-switch configurations.

PI

SA

SW6

SW7

SW8

Result

Left

Left

Left

Enables Link Segment mode (LS).

Right

Left

Left

Enables Link Propagate mode (LP).

Left

Right

Left

Enables Remote Fault Detection mode plus
Link Segment mode (RFD+LS).

Right

Right

Left

Enables Remote Fault Detection mode plus
Link Propagation mode (RFD+LP).

Left

Left

Right

Enables Symmetrical Fault Detect mode (SFD).

Right

Left

Right

Illegal setting. LS mode is enabled.

Left

Right

Right

Illegal setting. LS mode is enabled.

Right

Right

Right

Illegal setting. LS mode is enabled.

SW6

SW7

SW8

Result

Down

Down

Down

Enables Link Segment mode (LS).

Up

Down

Down

Enables Link Propagate mode (LP).

Down

Up

Down

Enables Remote Fault Detection mode plus
Link Segment mode (RFD+LS).

Up

Up

Down

Enables Remote Fault Detection mode plus
Link Propagation mode (RFD+LP).

Down

Down

Up

Enables Symmetrical Fault Detect mode (SFD).

Up

Down

Up

Illegal setting. LS mode is enabled.

Down

Up

Up

Illegal setting. LS mode is enabled.

Up

Up

Up

Illegal setting. LS mode is enabled.

NOTE: Connecting two converters set to any of the RFD modes are illegal and will cause a “deadly
embrace” lockup.
NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.

For detailed information on the operation of the different Link Modes, download the application note
iConverter Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

3.2.2

Board-Mounted Bank 2 Settings

PI

DIP-switch Bank 2 is only available on the plug-in module.

Switch

Left (Factory Default)

Right

SW1

A-DS:
Backplane Port A Disabled

A-EN:
Port A Enabled

SW2

B-DS:
Backplane Port B Disabled

B-EN:
Port B Enabled

SW3

Off:
Pause Disable

On:
Pause Enable

SW4

M/SL:
Master/Slave Auto-Select

SL:
Slave-Mode Only

SW5 - SW8 Reserved

Reserved

3.2.2.1

SW1 - Backplane Port A Enabled “A-DS/A-EN”

When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the 2GXM is
isolated from the chassis Backplane. When the DIP-switch is in the Right “A-EN” position, Backplane
Port A of the 2GXM is enabled. This port allows Ethernet Backplane connectivity to an adjacent module
via the chassis Backplane Port A. See the backplane illustrations in Section 2.1.3.

3.2.2.2

SW2 - Backplane Port B Enabled “B-DS/B-EN”

When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the
chassis Backplane. When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled.
This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B.
See the backplane illustrations in Section 2.1.3.