Product Overview

Omnitron’s iConverter CWDM/X Coarse Wave

Division Multiplexing (CWDM) Multiplexer/

Demultiplexer (MUX/DEMUX) modules support

ITU-T G.694.2 wavelengths between 1270nm

to 1610nm in 20nm increments. Up to sixteen

separate wavelengths can be transported over

a dual fiber common link.

The iConverter CWDM/X modules are available in 4 and 8-Channel models,

supporting a variety of wavelengths and optional port configurations.
Port Definitions

Figure 1: Port Locations for 4-Channel CWDM/X Module

Figure 2: Port Locations for 8-Channel Single-Wide CWDM/X Module

NOTE: The iConverter CWDM/X modules can not be installed in slots 4, 8, 12 and

16 of a 19-Module Chassis or in the top slot of a 2-Module Chassis or in a 1-Module

Redundant Power Chassis.
NOTE: The iConverter 8-Channel Double-Wide CWDM/X can only be installed

in a 2-Module Chassis or 19-Module Chassis with the exception of slots 4/5, 8/9,

12/13 and 16/17.

Design Considerations
iConverter CWDM/X modules are passive devices that require no external power.

Attenuation (signal loss) of less than 2.7dB will be realized through each port on the

module (see the CWDM/X Data Sheet for exact loss specification for each model).

Detailed calculations should be performed for each fiber optic link in the network to

ensure the proper optical devices are specified with sufficient transmitter power.
When calculating optical loss, ensure that the total loss, plus a safety factor (typically

3dB) does not exceed the optical power budget. The optical power budget is the

difference between the transmitter optical output power and the receiver’s optical

sensitivity. The transmitter optical output power and receiver optical sensitivity values

can be obtained from the manufacturers of the respective equipment. Please consult

the iConverter data sheets for CWDM/X signal loss specifications.
For more information, access Omnitron’s documentation download web page to

view all relevant documents:
http://www.omnitron-systems.com/downloads.php

Warranty

WARNING

The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any

servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron

Systems Technology.

Warranty

This product is warranted to the original purchaser against defects in material and workmanship for a period of ONE YEAR from the date

of shipment. You may register your product on the Internet at http://www.omnitron-systems.com. During the warranty period, Omnitron

will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping

charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by

Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal

of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental

specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site

preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any

particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special,

incidental, or consequential damages, whether based on contract, tort, or any legal theory.

040-08860-001B 1/09

Page 1

Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com

This manual is related to the following products: