2 module management mode, Module management mode – Omnitron Systems Technology iConverter 2GXM User Manual
Page 26
4.2
MODULE MANAGEMENT MODE
From the Module configuration screen, the management mode can be changed. Select option 18 to change
the mode. The management mode options will be displayed.
PI
Module - iConverter 2GXM iConverter, Serial Agent
Identifier -
Chassis Number
= 1
Switch ON condition
OFF condition
H/W
Actual
Slot Number
= 11
1: Port 1 Manual
Port 1 AN
Off
Off
Model Number
= 8999-0
2: Port 2 Manual
Port 2 AN
Off
Off
3: Not Available
Serial Number
= xxxxxxxx
4: Not Available
Manufacturing Date = xxxxxxxx
5: Not Available
Product Revision
= xx
6: Link Propagate
Link Segment
Off
Off
Software Revision
= xx
7: Remote Fault
Normal
Off
Off
8: Symm Fault Det
Normal
Off
Off
LED
9: BP A Enabled
BP A Disabled
Off
Off
1: Power
= On
10: BP B Enabled
BP B Disabled
Off
Off
2: Power Supply 1 = Off
11: Pause Enabled
Pause Disabled Off
Off
3: Power Supply 2 = Off
12: Slave Only
Master/Slave
Off
Off
4: Power Supply 3 = Off
13: Not Available
5: Port 1 Link = Off
14: Not Available
6: Not Available
15: Not Available
7: BP Master = Off
16: Not Available
8: Port 2 Link = Off
OAM settings:
9: Not Available
17: IP protocol State On
18: Management Mode Secure OAM
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The 2GXM module supports several management options. Option 18 configures how the module will
communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol. The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol. This option provides an industry standard
method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.
NOTE: See NetOutlook User Manual for complete information on the management modes.