PI

Module - iConverter 2GXM iConverter, Serial Agent

Identifier -

Chassis Number

= 1

Switch ON condition

OFF condition

H/W

Actual

Slot Number

= 11

1: Port 1 Manual

Port 1 AN

Off

Off

Model Number

= 8999-0

2: Port 2 Manual

Port 2 AN

Off

Off

3: Not Available

Serial Number

= xxxxxxxx

4: Not Available

Manufacturing Date = xxxxxxxx

5: Not Available

Product Revision

= xx

6: Link Propagate

Link Segment

Off

Off

Software Revision

= xx

7: Remote Fault

Normal

Off

Off

8: Symm Fault Det

Normal

Off

Off

LED

9: BP A Enabled

BP A Disabled

Off

Off

1: Power

= On

10: BP B Enabled

BP B Disabled

Off

Off

2: Power Supply 1 = Off

11: Pause Enabled

Pause Disabled Off

Off

3: Power Supply 2 = Off

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3 = Off

13: Not Available

5: Port 1 Link = Off

14: Not Available

6: Not Available

15: Not Available

7: BP Master = Off

16: Not Available

8: Port 2 Link = Off

OAM settings:

9: Not Available

17: IP protocol State On

18: Management Mode Secure OAM

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >

The Module configuration screen provides general information concerning the configuration and status of
the module. The screen displays the model and serial numbers, hardware and software revisions, as well as
the condition of the LEDs and DIP-switches. The DIP-switches can be re-configured (options 1 -12)
without removing the module from the chassis. Select the appropriate option to change the DIP-switch
setting. Selecting DIP-switch options 1 - 12, will cause the selection to change states under the ‘Actual’
heading.

NOTE: The Plug-In Module configuration screen is shown. The standalone Module configuration
screen will display LED 2, 3, 4, and 7 and DIP-switches 9, 10 and 12 as NOT AVAILABLE.