beautypg.com

4 configure the module via command line interface, Configure the module via command line interface – Omnitron Systems Technology iConverter 2GXM User Manual

Page 10

background image

3.4

CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

PI

SA

To configure, attach the 2GXM to a DB-9 serial (RS-232) equipped computer with terminal emulation
software such as HyperTerminal. The 2GXM Serial Console Port (DCE) is a mini DIN-6 female connector
which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a
serial cable to the serial port of the PC and the Serial Console Port of the 2GXM. This is a standard
asynchronous serial interface. The pin-outs are illustrated below.

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window.

Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the 2GXM module and press <ENTER> to bring up a command line prompt
on the attached PC.

The module is configured with the following defaults:

IP

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

WRITE:

public

SNMPv3 Parameters

User 1 name (read only):

guest

User 2 name (read/write):

admin

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin

Page 10