When the upload is complete, the 2GXM displays the update status and then automatically restarts with the
newly loaded firmware.

3.4.5.4

Updating the 2GXM Firmware via FTP

Using an FTP application, upload the new firmware into the FTP root directory of the 2GXM. When the
file transfer is complete, the 2GXM verifies the file and then automatically restarts with the newly loaded
firmware.

For detailed instructions on updating the management modules and other modules in the same chassis via
FTP, download the application note “iConverter Management: Updating Modules via FTP” available on
Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

See Setting 2GXM Passwords Section 3.4.1.4, on how to configure FTP.

3.5

VERIFY OPERATION

PI

SA

Once the module has been installed and configured, per Sections 3.2 - 3.4, verify the module is operational
by viewing the status of the LED indicators. The table below provides a description for each LED indicator.

The Power LED indicates the module is receiving power from the chassis or power cord. The plug-in
modules has an LED indicator for each available power supply in the chassis (the 19-Module Chassis has
three, the 5-Module Chassis has two).

The Fiber Optic LEDs (“P1” and “P2”) indicates the fiber optic connection between the modules have been
established. A blinking LED indicates the presence of data.

Refer to Section 6.0, Troubleshooting Guide, for help in determining possible fault conditions.

PI

SA

PI

SA

LED Function

"Legend"

Color

Off State

On / Blinking State

On / Blinking State

Power "Pwr"

Amber No power

On: Module has power

On: Module has power

Power Supply Status

#X

Amber

Chassis Power
Supply not installed

On: Power available from
installed Power Supply #X
Blinking: No power available

from installed Power Supply #X

Not available on standalone

Port 1
Fiber Link Activity
"P1"

Green No Fiber Link

On: Fiber link is active
Blinking: Fiber Data Activity

On: Fiber link is active
Blinking: Fiber Data Activity

Chassis Management
Master/Slave
"Msr/Slv"

Green

Chassis Slave
Mode

On: Chassis Master
Blinking: Operating in OAM
Mode

Not available on standalone

Port 2
Fiber Link Activity
"P2"

Green No Fiber Link

On: Fiber link is active
Blinking: Fiber Data Activity

On: Fiber link is active
Blinking: Fiber Data Activity