Communication and control, 300 v spiral shield, multiconductor, pvc, pvc – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual
Page 44
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
316
Cable > Communication, Control and Industrial > Multiconductor > Spiral Shield > 300 V
Communication and Control
300 V Spiral Shield, Multiconductor, PVC, PVC
AWM 2095
AWM 1108 (Single-conductor
cables)
Operating Temperature
• -20°C to +80°C
Conductor Color Coding
• 1 Black, 2 Red, 3 White, 4 Green,
5 Yellow, 6 Blue
Materials
• Stranded tinned copper
conductors
• PVC insulation
• Clear polyester wrap
(multiconductor only)
• Bare copper spiral shield,
95% coverage
• Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
22 AWG (0.35 mm
2
)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
2254/1
1
0.112
2.84
0.020
0.51
2254
2
0.177
4.50
0.020
0.51
2254/3
3
0.187
4.75
0.020
0.51
2254/4
4
0.206
5.23
0.020
0.51
2254/6
6
0.243
6.17
0.020
0.51
20 AWG (0.56 mm
2
)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
2256/1
1
0.119
3.02
0.020
0.51
2256
2
0.191
4.85
0.020
0.51
2256/3
3
0.202
5.13
0.020
0.51
2256/4
4
0.223
5.66
0.020
0.51
2256/6
6
0.264
6.71
0.020
0.51
18 AWG (0.81 mm
2
)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
2258/1
1
0.129
3.28
0.020
0.51
2258
2
0.214
5.44
0.020
0.51
2258/3
3
0.226
5.74
0.020
0.51
2258/4
4
0.247
6.27
0.020
0.51
16 AWG (1.32 mm
2
)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
2260
2
0.240
6.10
0.020
0.51
2260/3
3
0.254
6.45
0.020
0.51