beautypg.com

Rs-485 cable, 600 v shielded, multipair, Ul cm, cmg ul tc, pltc csa cm, cmg ft1 – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual

Page 26

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

298

Cable > Communication, Control and Industrial > Multipair > Shielded > 600 V

RS-485 Cable

600 V Shielded, Multipair

UL CM, CMG

UL TC, PLTC

CSA CM, CMG FT1

Operating Temperature

• -20°C to +60°C

Conductor Color Coding

• Chart M (page 518), except

6454

Materials

• Tinned copper conductors

• Foam high-density polyethylene

insulation

• Foil +65% tinned copper

braid shield

• Black PVC jacket

Features

• UL Sunlight Resistant

• 120-ohm nominal impedance

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin

• FIT-321: Medium-wall, adhesive-

lined, cross-linked polyolefin

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Part No.

Pairs

Nominal Diameter

Insulation Thickness

Jacket Thickness

Inch

mm

Inch

mm

Inch

mm

6453

1

0.284

7.21

0.028

0.71

0.042

1.07

6454*

1.5

0.300

7.62

0.032

0.81

0.042

1.07

6455

2

0.414

10.52

0.024

0.61

0.053

1.35

6456

3

0.414

10.52

0.022

0.56

0.053

1.35

6457

4

0.448

11.38

0.022

0.56

0.053

1.35

*Conductor color coding: white/orange-orange/white pair, white-blue single conductor.