beautypg.com

Solar cable, 600 v braid shield, multiconductor, pvc/nylon, pvc – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual

Page 18

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

290

Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V

Solar Cable

600 V Braid Shield, Multiconductor, PVC/Nylon, PVC

UL TC-ER

UL WTTC (1000 V)

UL MTW

CSA AWM I/II A/B FT1

Operating Temperature

• -40°C to +90°C (static)

• -30°C to +90°C (dynamic)

• +105°C (CSA)

Conductor Color Coding

• Chart F (page 520)

Materials

• Stranded bare copper

conductors

• PVC/nylon insulation

• Clear polyester wrap

• Tinned copper braid shield,

85% coverage

• Green PVC jacket

Features

• UL Sunlight Resistant

• UL Oil Res. I

• UL Direct Burial

• Suitable for use in Class I,

Division 2 locations per Article

501 of the National Electric Code

Availability

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-260: Cross-linked polyolefin

for ground identification

• FIT-300: Dual-wall polyolefin

with meltable inner wall

• FIT-750: Bonding adhesive-lined

cross-linked polyolefin

18 AWG (0.96 mm

2

)

Stranding: 19/30 (19 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

SPM1803CY

3

0.329

8.36

0.050

1.27

SPM1804CY

4

0.354

8.99

0.050

1.27

SPM1805CY

5

0.381

9.68

0.050

1.27

SPM1807CY

7

0.409

10.39

0.050

1.27

SPM1809CY

9

0.466

11.84

0.050

1.27

16 AWG (1.32 mm

2

)

Stranding: 26/30 (26 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

SPM1603CY

3

0.351

8.92

0.050

1.27

SPM1604CY

4

0.378

9.60

0.050

1.27

SPM1605CY

5

0.408

10.36

0.050

1.27

SPM1607CY

7

0.439

11.15

0.050

1.27

SPM1609CY

9

0.509

12.93

0.050

1.27

14 AWG (2.08 mm

2

)

Stranding: 41/30 (41 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

SPM1403CY

3

0.381

9.68

0.050

1.27

SPM1404CY

4

0.412

10.46

0.050

1.27

SPM1405CY

5

0.446

11.33

0.050

1.27

SPM1407CY

7

0.481

12.22

0.050

1.27

SPM1409CY

9

0.590

14.99

0.065

1.65

12 AWG (3.29 mm

2

)

Stranding: 65/30 (65 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

SPM1203CY

3

0.422

10.72

0.050

1.27

SPM1204CY

4

0.458

11.63

0.050

1.27

SPM1205CY

5

0.497

12.62

0.050

1.27

SPM1207CY

7

0.574

14.58

0.065

1.65

SPM1209CY

9

0.659

16.74

0.065

1.65