Solar cable, 600 v braid shield, multiconductor, pvc/nylon, pvc – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual
Page 18
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
290
Cable > Communication, Control and Industrial > Multiconductor > Braid Shield > 600 V
Solar Cable
600 V Braid Shield, Multiconductor, PVC/Nylon, PVC
UL TC-ER
UL WTTC (1000 V)
UL MTW
CSA AWM I/II A/B FT1
Operating Temperature
• -40°C to +90°C (static)
• -30°C to +90°C (dynamic)
• +105°C (CSA)
Conductor Color Coding
• Chart F (page 520)
Materials
• Stranded bare copper
conductors
• PVC/nylon insulation
• Clear polyester wrap
• Tinned copper braid shield,
85% coverage
• Green PVC jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I
• UL Direct Burial
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-260: Cross-linked polyolefin
for ground identification
• FIT-300: Dual-wall polyolefin
with meltable inner wall
• FIT-750: Bonding adhesive-lined
cross-linked polyolefin
18 AWG (0.96 mm
2
)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
SPM1803CY
3
0.329
8.36
0.050
1.27
SPM1804CY
4
0.354
8.99
0.050
1.27
SPM1805CY
5
0.381
9.68
0.050
1.27
SPM1807CY
7
0.409
10.39
0.050
1.27
SPM1809CY
9
0.466
11.84
0.050
1.27
16 AWG (1.32 mm
2
)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
SPM1603CY
3
0.351
8.92
0.050
1.27
SPM1604CY
4
0.378
9.60
0.050
1.27
SPM1605CY
5
0.408
10.36
0.050
1.27
SPM1607CY
7
0.439
11.15
0.050
1.27
SPM1609CY
9
0.509
12.93
0.050
1.27
14 AWG (2.08 mm
2
)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
SPM1403CY
3
0.381
9.68
0.050
1.27
SPM1404CY
4
0.412
10.46
0.050
1.27
SPM1405CY
5
0.446
11.33
0.050
1.27
SPM1407CY
7
0.481
12.22
0.050
1.27
SPM1409CY
9
0.590
14.99
0.065
1.65
12 AWG (3.29 mm
2
)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.12 mm) nylon
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
SPM1203CY
3
0.422
10.72
0.050
1.27
SPM1204CY
4
0.458
11.63
0.050
1.27
SPM1205CY
5
0.497
12.62
0.050
1.27
SPM1207CY
7
0.574
14.58
0.065
1.65
SPM1209CY
9
0.659
16.74
0.065
1.65