beautypg.com

Communication and control cable, 300 v foil shielded, multipair, lszh, Ul cm vw-1 csa cmg ft4 – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual

Page 32

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

304

LSZH Overall Foil Shielded Multipair

Conductor Color Coding: Chart A

24 AWG (0.22 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5471L

1

0.161

4.09

0.028

0.71

5472L

2

0.209

5.31

0.028

0.71

5473L

3

0.228

5.79

0.028

0.71

5474L

4

0.240

6.10

0.028

0.71

5475L

5

0.272

6.91

0.030

0.76

5476L

6

0.299

7.59

0.030

0.76

5477L

7

0.299

7.59

0.030

0.76

5478L

8

0.319

8.10

0.032

0.81

5479L

9

0.339

8.61

0.032

0.81

5480L

10

0.378

9.60

0.032

0.81

LSZH Individually Foil-Shielded Pair

Conductor Color Coding: Chart A

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.010 (0.25 mm)

Part No.

Pairs

Nominal Diameter

Jacket Thickness

Insulation Thickness

Inch

mm

Inch

mm

Inch

mm

2466L*

2

0.161

4.09

0.014

0.35

0.009

0.22

6010L

3

0.299

7.59

0.047

1.19

0.010

0.25

2463L*

4

0.242

6.15

0.020

0.50

0.008

0.20

6012L

6

0.386

9.80

0.040

1.01

0.010

0.25

6014L

9

0.441

11.20

0.040

1.01

0.010

0.25

6017L

12

0.492

12.50

0.040

1.01

0.010

0.25

Alpha Wire’s LSZH communica-
tion and control cable combines
LSZH-rated insulation and jackets
with the rugged performance
you expect from Alpha. The
specially formulated LSZH material
minimizes the effects from smoke
and harmful corrosive gases in the
event of combustion. Low smoke
means easier visibility in exiting
the area and reduced danger of
smoke inhalation, while low toxicity
means no harm to people from
halogenated gases.

UL CM VW-1

CSA CMG FT4

Operating Temperature

• -20°C to +75°C

Materials

• Stranded tinned copper

conductors

• LSZH insulation

• Aluminum/polyester shielding,

with 25% overlap min.

Foil facing inward

Tinned copper drain wire sized

the same as the conductors

• Slate LSZH jacket

LSZH Properties

• LSZH Flammability:

Passes IEC 60332-1

• LSZH Acid Gas Generation:

Passes IEC 60754-1 and 60754-2

• LSZH Smoke Emission:

Passes IEC 61034-2

Cable > Communication, Control and Industrial > Low-Smoke, Zero-Halogen (LSZH)

Communication and Control Cable

300 V Foil Shielded, Multipair, LSZH

*Conductor color coding: 1 Red-Black, 2 Green-White, White/Red-White/Black, 4 White/Green-White/Yellow.