Cable > Communication, Control and Industrial > Shielded > 600/1000 V

Series V VFD Control Cables

Enhanced Design for Superior Performance in Variable-Frequency Drives

600/1000 V Shielded

Series V cables for variable-frequency

drives (VFD) set the standard in high-

performance and reliable connectivity.

Their specially formulated cross-linked

polyethylene insulation provides superior

corona resistance, low capacitance

for longer runs, and excellent low-

temperature properties.
A symmetrical design places the ground

wires in the interstices of the conductors

for uniform conductor-to-ground

capacitance and impedance.
Smaller gauge cable feature a combination

foil/braid shield to offer exceptional

EMI/RFI protection in noisy environments.

On larger gauge cable, a double copper

tape is used to provide the same noise-

free operation.
This uniformity reduces the probability

of motor damage from common-mode

current.
Alpha Series V VFD cables are compatible

with drives from all major manufacturers.

UL RHW-2 (16 – 2 AWG)

UL XHHW-2

UL TC-ER

UL 1000V Flexible Motor

Supply Cable

CSA AWM I/II A/B FT4

CE LVD 73/23/EEC

Amendment 93/68/EEC

Pennsylvania MHSA

Operating Temperature

• -40°C to +90°C

Conductor Color Coding

• Black, numbered

Materials

• Stranded tinned copper

conductors

• Stranded tinned copper

ground wires

• Cross-linked polyethylene

insulation

• Shielding

16 – 4 AWG:

Aluminum/polyester/aluminum

foil and tinned copper braid

with 85% coverage

2 – 4/0 AWG:

Double-layer copper tape

• Black premium PVC jacket

Voltage

• 600 V (UL TC-ER)

• 1000 V (UL Motor Supply)

Features

• UL Direct Burial

• UL Sunlight Resistant

• 10x bend radius

• Suitable for use in Class I,

Division 2 locations per Article

501 of the National Electric Code

Availability

Bulk, made to order

FIT® Tubing Recommendations

• FIT-221: General-purpose

cross-linked polyolefin

• FIT-321V: Low-shrink-

temperature, flame-retardant

cross-linked polyolefin

Three-Conductor VFD Cables

Part No.

Wire Size

Stranding

Shielding

Insulation Thickness

Jacket Thickness

Nominal Diameter

AWG

mm

2

AWG

mm

Inch

mm

Inch

mm

Inch

mm

V16316

16

1.32

26/30

26 x 0.25

Foil/Braid

0.046

1.17

0.050

1.27

0.468

11.89

V16314

14

2.09

41/30

41 x 0.25

Foil/Braid

0.046

1.17

0.065

1.65

0.538

13.67

V16312

12

3.31

65/30

65 x 0.25

Foil/Braid

0.046

1.17

0.065

1.65

0.578

14.68

V16310

10

5.37

105/30

105 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.642

16.31

V16308

8

8.53

133/29

133 x 0.28

Foil/Braid

0.061

1.55

0.065

1.65

0.798

20.27

V16306

6

13.57

133/27

133 x 0.36

Foil/Braid

0.061

1.55

0.085

2.15

0.924

23.47

V16304

4

21.58

133/25

133 x 0.45

Foil/Braid

0.061

1.55

0.085

2.15

1.050

26.67

V16302

2

34.32

133/23

133 x 0.57

Tape

0.061

1.55

0.085

2.15

1.157

29.39

V16001

1

43.28

133/22

133 x 0.64

Tape

0.056

1.42

0.085

2.15

1.197

30.48

V16000

1/0

54.58

133/21

133 x 0.72

Tape

0.056

1.42

0.085

2.15

1.294

32.77

V16020

2/0

68.85

133/20

133 x 0.81

Tape

0.056

1.42

0.085

2.15

1.399

35.56

V16030

3/0

86.9

133/19

133 x 0.91

Tape

0.056

1.42

0.085

2.15

1.517

38.53

V16040

4/0

109

133/18

133 x 1.02

Tape

0.056

1.42

0.085

2.15

1.653

41.98