Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
308
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 600 V
Communication and Control
600 V Unshielded, Multiconductor, PVC, PVC
UL AWM 2463 VW-1
Operating Temperature
• -20°C to +80°C
Conductor Color Coding
• Chart F (page 520)
Materials
• Stranded tinned copper
conductors
• PVC insulation
• Clear polyester wrap
• Slate PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
16 AWG (1.32 mm
2
)
Stranding 19/0.0117 (19 x 0.29 mm)
Insulation Thickness 0.032 (0.81 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
1064
4
0.395
10.03
0.047
1.19
1065
5
0.430
10.92
0.047
1.19
1067
7
0.468
11.89
0.047
1.19
1069
9
0.577
14.66
0.063
1.60
1072
12
0.640
16.26
0.063
1.60
1075
15
0.694
17.63
0.063
1.60
1079
19
0.749
19.02
0.065
1.65
1085
25
0.907
23.04
0.083
2.11
14 AWG (2.08 mm
2
)
Stranding (19 x 0.0147 (19 x 0.37 mm)
Insulation thickness: 0.047 (1.19 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
1274
4
0.503
12.78
0.047
1.19
1275
5
0.584
14.83
0.063
1.60
1277
7
0.635
16.13
0.063
1.60
1279
9
0.744
18.90
0.065
1.60
1282
12
0.867
22.02
0.083
2.11