D-sub, Standard smc connectors technical characteristics – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual
Page 179
05
178
D-Sub
M
F
M
F
M
F
M
F
D-Sub
Standard SMC connectors
Technical characteristics
Current carrying capacity
The current carrying capacity is limited by maximum temperature
of materials for inserts and contacts including terminals.
The current capacity-curve is valid for continuous, not interrupted
current-loaded contacts of connectors when simultaneous power
on all contacts is given, without exceeding the maximum tempera-
ture.
Control and test procedures according to DIN IEC 60 512.
Contact arrangement
View from termination side
Mating conditions
as per DIN 41 652
M = Male connector
F = Female connector
37 way
W
or
king current
Ambient temperature
Example: 25 way connector
➀
Stamped contacts
1)
Performance level 3, 50 mating cycles, no gas test
Performance level 2 as per CECC 75 301-802, 250 mating cycles, 4 days 4 mixed gas test – IEC 60 512
Performance level 1 as per CECC 75 301-802, 500 mating cycles, 10 days 4 mixed gas test – IEC 60 512
9 way
15 way
25 way
Number of contacts
9, 15, 25, 37
UL recognized
Working current
see current carrying capacity chart
Stamped contacts
6.5 A max.
Test voltage U
r.m.s.
1 kV
Clearance and creepage
≥ 1.0 mm
Contact resistance
≤ 10 mΩ
Insulation resistance
≥ 10
10
Ω
Temperature range
-55
O
C … +125
O
C
during reflow soldering
max. + 240
O
C for 15 s
The higher temperature limit includes the local ambient and
heating effect of the contacts under load. All connectors are
suitable for standard reflow processes.
Terminations
a) Solder pins Ø 0.6 mm for
P.C.B. holes Ø 0.8/1 mm
b) Solder pins, angled 90
O
Ø 0.6 mm for P.C.B. holes
Ø 1 mm
Materials
Mouldings
Thermoplastic resin, glass-
fibre filled (PCT),
UL 94-V0
Contacts
Copper alloy
Contact surface
Contact zone
selectively plated according
to performance level
1)
Metal shell
Plated steel
Insertion and withdrawal force
Connector on P.C.B.
Solder, straight with clips
– insertion max. per connector:
≤
60 N
– withdrawal min. per connector:
≤
10 N
Mating force
9 way ≤ 30 N
15 way ≤ 50 N
25 way ≤ 83 N
37 way ≤ 123 N