D-sub housing range – Northern Connectors Harting D-sub Connectors, Housings & Accessories User Manual
Page 166
05
165
D-Sub
Mounting details
Crimp flange termination instruction
1. Strip the cable sheath to the correct length
(approx. 35 to 40 mm, depending on interface
type).
2. Place the crimp ferrule over the cable sheath.
Bend the outer screen backwards over the
cable sheath. Cut screen approx. 2 mm from
the end of the cable sheath.
3. Place the crimp flange over the wires covered
by the remaining foil shield. Push and twist
the crimp flange under the outer screen
and cable sheath until the end of the cable
sheath touches the crimp flange. HARTING
has
developed a special tool for optimised
installation of the shielding over the crimp
flange, part number 61 03 600 0017.
4. Move the crimp ferrule back onto the crimp
flange and crimp the two parts together with
the special service crimp tool part number
61 03 600 0020. For an optimised crimp process
the tool should to be positioned as close as
possible to the crimp flange sholder.
5. Cut off the internal screen foil and push the
crimp flange inside the metal hood.
HARTING offers to test and define the best
crimp flange and ferrule combination for
customer specific cables.
D-Sub Housing range