Circuit Breakers and Starter Relays

Thermal circuit breakers and Glow Plug Starter Relays are
located behind the console access cover at the top of the console.

Figure 60. Circuit Breakers and Starter Relay

Under normal circumstances the circuit breakers do not require
service. They automatically re-set when an overload condition
is corrected. If a breaker is cycling on and off, locate the cause of
the electrical overload and repair as required.

Maximum Cut Depth Adjustment

The saw comes factory-adjusted for maximum usable cut depth.
Should this setting need to be changed, perform the following:

1.

With the BLADE REMOVED, park the saw on a flat and
level surface.

2.

Fully lower the saw onto the Depth Limiting Stop Bolts.

3.

Measure the distance from the Blade Flanges to the surface.

4.

If adjustment is required, loosen Locknut on the right-side
Depth Limiting Stop Bolt and screw bolt in several turns
until it no longer makes contact with the axle.

Figure 61. Depth Adjustment

1.

Left-Side Stop Bolt

2.

Right-Side Stop Bolt

3.

Blade Flanges

4.

Blade Shaft Housing

5.

Adjust the left-side Stop Bolt in or out until the Blade Flange
or Lower Belt Guard achieves 1/8" to 3/16" ground
clearance. Tighten lock nut on left side.

6.

Raise saw and place 2 jack stands under the Blade Shaft
Housing.

7.

While holding the Raise-Lower Switch in the Lowering
Position, raise the front axle assembly until it contacts the
left-side Depth Limiting Stop Bolt.

8.

While holding the axle firmly against the left-side Depth
Limiting Stop Bolt, screw the right-side Depth Stop Limiting
Bolt out until it makes contact with the axle. Tighten lock
nut on right side.

Following this procedure will prevent torsional stresses being
applied to the frame when fully lowered due to uneven adjustment
of Depth Limiting Stop Bolts.

PS7060 MULTIQUIP SAW — MAINTENANCE

3

4

While adjustment of the Depth Stop Limiting
Bolts can change the maximum usable cut
depth, they should not be adjusted to
compensate for unit "wobble" or blade/cut
problems. These indications are a result of other
issues that should be addressed.

1

2

1. Circuit Breakers

2.

Relay, Glow Plug

3.

Delay Timer

4.

Starter Relay

This manual is related to the following products: