Ps7060 multiquip saw — maintenance, Warning – Multiquip PS706036 User Manual
Page 48
PAGE 48 — PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08)
Figure 57. Blade Flange Puller
Correct removal or installation of the Inner Blade Flange requires
Flange Puller (p/n 18503) as shown in figure 57.
Blade Flange Removal/Installation
If unfamilar with this operation seek assistance or training
from someone that is familar with this operation. Because of
the tapered fit between the Blade Flange and Blade Shaft,
5-10 tons of force is required to release the inner flange from
the Blade Shaft. Both parts and tools can become dangerous
projectiles if instructions are not followed properly.
WARNING
WARNING
WARNING
WARNING
WARNING
Removing the Inner Blade Flange
1.
With the Outer Blade Flange in place, loosen the Blade
Mounting Bolt approximately 1/4".
4.
With the Outer Blade Flange in place, loosen the Blade
Mounting Bolt approximately 1/4".
5.
While the 3 perimeter bolts hold the two Puller Plates
together, slide the Horseshoe Plate of the Flange Puller
behind the (Shaft) side of the Inner Flange.
6.
Tighten the center puller bolt to remove the Inner Flange
from the Blade Shaft.
The Outer Flange MUST be in place to prevent the Puller
assembly and Inner Flange from flying off when the taper
breaks loose. Injury or equipment damage could otherwise
result.
WARNING
WARNING
WARNING
WARNING
WARNING
3.
Lock down the Transaxle Attachment Bolts when the
appropriate alignment distance is set.
Figure 56. Drive Wheel Alignment Bolt
Locations
1.
Pivot Attachment Bolt
2. Adjustment Attachment Bolts
3. Adjustment Screw
PS7060 MULTIQUIP SAW — MAINTENANCE
1.
Blade Flange
2. Horseshoe Puller Plate
3. Puller Plate
4. Perimeter Bolt
5. Center Puller Bolt
2.
While the 3 perimeter bolts hold the two Puller Plates
together, slide the Horseshoe Plate of the Flange Puller
behind the (Shaft) side of the Inner Flange.
3.
Tighten the Bolt Head.
3
1
2