Static performance specifications, Dynamic performance specifications – MTS Series 256 Servovalve User Manual
Page 18
![background image](/manuals/568080/18/background.png)
Series 256 Servovalve Product Information
18
Specifications
Introduction
Static Performance Specifications
Values are typical for Series 256 Servovalves operated at the recommended
hydraulic fluid filtration levels.
Dynamic Performance Specifications
The dynamic data is derived from typical Model 256 Servovalve driven with a
valve controller with “rate” compensation. A constant amplitude sine wave was
used as the input signal to the valve controller. The amplitude was plus-or-minus
the main stage, full-stroke, and LVDT voltage.
M
ODEL
*
R
ATED
F
LOW
N
OMINAL
G
AIN
P
RESSURE
G
AIN
P
RESSURE
C
OEFFICIENT
N
ULL
F
LOW
L/
MIN
GPM
L/
MIN
/
%
STROKE
GPM
%
STROKE
(%
SUPPLY
/
%
STROKE
)
CM
3
/
KGF
-
SEC
IN
3
/
SEC
/
PSI
)
L/
MIN
GPM
256.04
150
40
2.2
0.58
100
0.30
1.3x10-3
9.5
2.5
256.09
340
90
6.0
1.6
150
0.56
2.4x10-3
13.0
3.5
256.18
680
180
10.6
2.8
200
0.73
3.1x10-3
21.0
5.5
256.25
950
250
16.0
4.2
160
1.38
5.9x10-3
23.8
6.3
256.40
1500
400
29.0
7.7
250
1.38
6.9x10-3
20.4
7.5
M
ODEL
*
R
ATED
F
LOW
P
ILOT
F
LOW
F
ULL
F
LOW
F
REQUENCY
90º P
HASE
S
IGNAL
†
S
POOL
S
TROKE
R
ISE
T
IME
(T
R
)
(
MILLISECONDS
)
L/
MIN
GPM
L/
MIN
GPM
H
Z
H
Z
90% O
PEN
10% O
PEN
256.04A-01
150
40
3.8
1
80
130
4.8
3
256.09A-01
256.09A-02
340
340
90
90
3.8
9.5
1
2.5
30
80
120
130
9
4.6
3.5
4.3
256.18C-01
256.18C-02
256.18C-05
680
680
680
180
180
180
3.8
9.5
19
1
2.5
5
20
30
50
90
100
100
12
7
5.5
3
2.2
1.8
* Performance information is provided for the models listed. Contact MTS for performance information
for Models 256.18D and 256.xxB.
† At 10% spool stroke.
‡ These are estimated values. All other values are typical.