Connecting cables, On/off (model 298.11 only), Proportional valve (model 298.12 only) – MTS Series 298 Hydraulic Service Manifold User Manual
Page 30: Connecting cables 30
![background image](/manuals/568002/30/background.png)
Series 298 Hydraulic Service Manifold
30
Connecting Cables
Installation
Connecting Cables
The actuator manifold has three possible electrical connections.
•
On/off control of the station (actuator) pressure (Model 298.11 only)
•
Proportional control of the station (actuator) pressure (Model 298.12 only)
•
Dirty filter indication (option for all models)
Note
Controllers usually label the connection to the actuator manifold as HSM
(hydraulic service manifold). The actuator manifold functions the same
as a hydraulic service manifold.
On/off (Model 298.11
only)
The on/off solenoid valve connects to the system controller (or a hydraulic
control panel). MTS Systems Corporation controllers label this connection HSM.
See the controller manual for cabling information.
Proportional valve
(Model 298.12 only)
The proportional valve connects to the system controller. MTS Systems
Corporation controllers that support proportional valves label this connection
HSM Proportional (or Prop HSM). See the controller product manual for cabling
information. If you are not sure if your controller supports a proportional output,
contact MTS Systems Corporation.
On/Off
Solenoid
Valve
From
Controller
24 Vdc
P1
J1
A
A
B
B
Com
Proportional
Valve
From
Controller
P1
J1
A
A
B
B
- Proportional Valve
+ Proportional Valve