beautypg.com

Specifications, General specifications, Specifications 19 – MTS Series 298 Hydraulic Service Manifold User Manual

Page 19: General specifications 19

background image

Specifications

Series 298 Hydraulic Service Manifold

Introduction

19

Specifications

General Specifications

PARAMETER

SPECIFICATION

Operating pressure

21 MPa (3000 psi)

Maximum average full flow

*

(high

pressure mode)

* With dual 56 L/min (15 gpm) servovalves.

114 L/min (30 gpm)

Maximum peak flow

182 L/min. (48 gpm)

Pressure drop through manifold
(less filter)

<0.7 MPa @ 114 L/min (<100 psi @ 30 gpm)

Filtration (optional)

3 micron (Beta3 = 75) or 10 micron (Beta7.4 = 75)

THE FOLLOWING ONLY APPLY TO THE MODEL 298.11

On/off solenoid valve

0 V DC= Off 24 V DC= On

THE FOLLOWING ONLY APPLY TO THE MODEL 298.12

Variable low pressure setting

† Adjustable at the controller.

0.7 to 7 MPa (100 to 1000 psi)

Low-to-high, high-to-low ramp
time

2 to 5 seconds

Ramp time for rapid shutoff

550 ms

Maximum pressure transient

0.7 MPa (100 psi)

Maximum current to the electrical
pressure reducing valve

0.8 A