beautypg.com

Routine maintenance overview checklist, Routine maintenance overview checklist 54 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-11 User Manual

Page 54

background image

Model 505G2.07/.11 SilentFlo™ HPU

54

Routine Maintenance Overview Checklist

Routine Maintenance Overview Checklist

Recommended service to be performed at each running time interval noted

Calendar Time using 8 hour
Running Time rate per day

Daily

Weekly

Monthly

Annually

Running Time-Hours

8

40

160

500

1000 1,500 2,000

5,000 10,000

Check electronic enclosure
ventilation

X

*

Check dirty filter indicators

X

Check for leaks

X

Check oil level

X

Check pressure

X

Check fluid color and odor

X

Check interlock devices

X

Check cables and connectors

X

Check console air filter

MTS

Check all accumulators for
proper precharge pressure
and oil

MTS

MTS

MTS

MTS

Check condition of all
electrical cables and cable
connections

MTS

MTS

MTS

MTS

Check HPU hydraulic fluid
color and odor

MTS

MTS

MTS

MTS

Check HPU operating pressure
and temperature

MTS

MTS

MTS

MTS

Clean control cabinet air filter,
replace if required

MTS

MTS

MTS

MTS

Inspect heat exchanger for
leaks or “flow (when off)”

MTS

MTS

MTS

MTS

Inspect pump hoses for leaks

MTS

MTS

MTS

MTS

Lubricate-grease motor
bearings (non 505)

MTS

MTS

MTS

MTS

Verify dirty filter indicators
status

MTS

MTS

MTS

MTS

Verify HPU hydraulic fluid level

MTS

MTS

MTS

MTS

Verify warning and interlock
devices

MTS

MTS

MTS

MTS

This manual is related to the following products: