DIAMOND BLADE CHANGE-OUT

MK-101 Pro24

MAINTENANCE

(A)

Locate the Shaft Lock push-

button on the underside of the

Cutting Head.

(B)

Remove Retaining Nut and

Outer Flange, depress and hold

the Shaft Lock pushbutton and

loosen.

(C)

Remove the Diamond Blade.

(D)

Install the Diamond Blade

onto Blade Shaft.

(E)

Verify the Blade is seated on

the Blade Shaft and direction

of rotation is correct.

(F)

Install Retaining Nut and Outer

Flange, depress and hold the

Shaft Lock pushbutton and

tighten Retaining Nut.

NOTE: When installing the Retaining Nut, do not “cross-thread” and DO NOT over tighten

the retaining nut.