METAL SALES MANUFACTURING CORPORATION
R9697
Mechanically attached metal roof panels - Type “Vertical Seam” secured by steel anchor clips.
Anchor clips are attached to a hat shaped member* (minimum depth 1 in.) or a bearing plate**.
For use in Design Nos. P224 , P225 , P227 , P230 , P237 , P508 , P510 , P512 , P701 , P711 , P712
, P713 , P715 , P717 , P720 , P722 , P723 , P724 , P726 , P731 , P734 , P736 , P803 , P814 , P815 ,
P818 , P819 , P821 , P823 , P824 .
*Hat shaped member to be a minimum of 16 gauge. The member will be fastened through the roof
insulation to the steel roof deck with min. No. 14 self-drilling and/or self-tapping fasteners. Spacing
to be determined by the structural loading requirements. In addition any compressible UL Classified
glass fiber blanket insulation with or without a vapor retarder facing may be used between the speci-
fied roof insulation and the metal roof panels.
**Bearing plate to be a minimum of 16 gauge. Member will be fastened through the roof insulation to
the steel deck with min. No. 14 self-drilling and/or self-tapping fasteners.
See the UL Fire Resistance Directory for explanation of each design number listed above.
Underwriters Laboratories Inc.
®
UL
®
LISTED
PVS-13
VERTICAL SEAM
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11