9400 Technology applications | Actuator – torque
Parameter setting & configuration
Speed limit value conditioning
Use of further ramp parameter sets
If required, 15 further ramp parameter sets can be parameterised. For the selection of the
ramp parameter sets 1 ... 15, the selection inputs are to be assigned with the corresponding
signals. The selection of the ramp parameter sets is carried out in a binary coded manner.
r
Parameter setting: Tab Application parameters dialog level Overview Ramp
generator All ramp parameters
Parameter
Lenze setting
Value Unit
C03512/1
Acceleration time 1
0.000 s
C03512/...
Acceleration time ...
... ...
C03512/15
Acceleration time 15
0.000 s
C03513/1
Deceleration time 1
0.000 s
C03513/...
Deceleration time ...
... ...
C03513/15
Deceleration time 15
0.000 s
C03514/1
S-ramp time 1
0.000 s
C03514/...
S-ramp time
... ...
C03514/15
S-ramp time 15
0.000 s
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Activate ramp parameter set 1 a
C03009/8
FALSE Activate ramp parameter set 2
C03009/9
FALSE Activate ramp parameter set 4
C03009/10
FALSE Activate ramp parameter set 8 a
C03009/11