9400 Technology applications | Actuator – torque
Parameter setting & configuration
Torque setpoint conditioning
4.4.1
Setpoint inversion
[4-3]
Setpoint inversion (schematic diagram)
Via the digital input DI3 the effective direction of the (bipolar) setpoint can be inverted, if
required.
r
Parameter setting: All parameters tab category Actuator - torque Multiplexer
4.4.2
Ramp generator
[4-4]
Ramp generator (schematic diagram)
In order to avoid setpoint step-changes the torque setpoint passes a ramp generator with
a parameterisable acceleration/deceleration and S-ramp time before it is transmitted to
the basic drive function "Torque follower".
r
Parameter setting: Application parameters tab dialog level Overview
M
Gain
Invert setpoint
LS_Torque...
M
Torque
setpoint
DI2
DI3
OUT
IN
Ramp generator
Status
machine
(basic drive
functions)
Torque setpoint
AIN1
v
F
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DIGIN 3 Invert setpoint
C03003
M
Gain
Invert setpoint
LS_Torque...
M
Torque
setpoint
DI2
DI3
OUT
IN
Ramp generator
Status
machine
(basic drive
functions)
Torque setpoint
AIN1
v
F
Parameter
Lenze setting
Value Unit
C03550
Acceleration / deceleration time
0.010 s
C03551
S-ramp time
0.001 s