Machine parameters
4.3
Machine parameters
O
Tip!
In the »Engineer« the most important machine parameters can be adapted to the
machine on the Application parameter tab directly in the topmost Overview dialog
level:
Short overview of machine parameters
The machine parameters describe e.g. the motor end of the mechanics
used.
The setting of the machine parameters in the »Engineer» is carried out on
the Application parameters tab in the dialog level Overview Drive
interface .
Parameter
Lenze setting
Value Unit
C00173
Mains voltage
400/415 V
C00174
Undervoltage (LU) threshold
285 V
C00600
Resp. to DC bus overvoltage
Trouble
C02520
Gearbox factor numerator: Motor
1
C02521
Gearbox factor denom: Motor
1
C02527
Motor mounting direction
Motor rotating CW
C02570
Position control structure
Phase control
C02522
Gearbox factor num.: Pos. enc.
1
C02523
Gearbox factor denom.: Pos. enc.
1
Description of the mechanics (load, tool)
C02528
Traversing range
Unlimited
C02524
Feed constant
360.0000 unit
C02525
Unit
°
C02526
User-defined unit
°
C02533
Time unit
s
C00273/1
Motor moment of inertia
Motor-dependent kg cm
2
C00273/2
Load moment of inertia
0.00 kg cm
2
M