Reference – Lenze E94P PositionServo Modbus User Manual
Page 34

34
P94MOD01C
Reference
Index
Name
Type
Format
EPM
Access
Description
Range
Unit
RAM
Registers
32bit
Integer
Access
4X
Register #
RAM
Register
32bit
Float
Access
4X
Register #
EPM
Reg Copy
32bit
Integer
Access
4X
Register #
EPM
Reg Copy
32bit
Float
Access
4X
Register #
RAM
Register
16bit
Signed
Integer
4X
Register #
EPM
INT16
4X
Register #
121
VAR_V21
F
Y
R/W
User variable
243
755
1267
1779
2170
2426
122
VAR_V22
F
Y
R/W
User variable
245
757
1269
1781
2171
2427
123
VAR_V23
F
Y
R/W
User variable
247
759
1271
1783
2172
2428
124
VAR_V24
F
Y
R/W
User variable
249
761
1273
1785
2173
2429
125
VAR_V25
F
Y
R/W
User variable
251
763
1275
1787
2174
2430
126
VAR_V26
F
Y
R/W
User variable
253
765
1277
1789
2175
2431
127
VAR_V27
F
Y
R/W
User variable
255
767
1279
1791
2176
2432
128
VAR_V28
F
Y
R/W
User variable
257
769
1281
1793
2177
2433
129
VAR_V29
F
Y
R/W
User variable
259
771
1283
1795
2178
2434
130
VAR_V30
F
Y
R/W
User variable
261
773
1285
1797
2179
2435
131
VAR_V31
F
Y
R/W
User variable
263
775
1287
1799
2180
2436
132
VAR_MOVEDR_DISTANCE
F
N
W
Registered move distance.
Incremental motion as per MOVEDR
statement
UU
265
777
1289
1801
2181
2437
133
VAR_MOVEDR_
DISPLACEMENT
mtn
F
N
W
Registered move displacement. Writing to
this variable executes the move MOVEDR
using value set by #132
UU
267
779
1291
1803
2182
2438
134
VAR_MOVEPR_DISTANCE
F
N
W
Registered move distance.
Absolute motion as per MOVEPR statement
UU
269
781
1293
1805
2183
2439
135
VAR_MOVEPR_
DISPLACEMENT
mtn
F
N
W
Registered move displacement. Writing to
this variable makes the move MOVEPR using
value set by #134
UU
271
783
1295
1807
2184
2440
136
VAR_STOP_MOTION
W
N
W
Stops motion
0 - no action; 1 - stops motion
0 - 1
273
785
1297
1809
2185
2441
137
VAR_START_PROGRAM
W
N
W
Starts user program
0 - no action; 1 - starts program
0 - 1
275
787
1299
1811
2186
2442
138
VAR_VEL_MODE_ON
W
N
W
Turns on Profile Velocity for Internal Position
Mode
0 - normal operation; 1 - velocity mode on
0 - 1
277
789
1301
1813
2187
2443
139
VAR_IREF
F
N
W
Reference: Internal Torque or Velocity Mode
RPS
Amps
279
791
1303
1815
2188
2444
140
VAR_NV0
F
N
R/W
User defined Network variable
281
793
1305
1817
2189
2445
141
VAR_NV1
F
N
R/W
User defined Network variable
283
795
1307
1819
2190
2446
142
VAR_NV2
F
N
R/W
User defined Network variable
285
797
1309
1821
2191
2447
143
VAR_NV3
F
N
R/W
User defined Network variable
287
799
1311
1823
2192
2448
144
VAR_NV4
F
N
R/W
User defined Network variable
289
801
1313
1825
2193
2449
145
VAR_NV5
F
N
R/W
User defined Network variable
291
803
1315
1827
2194
2450
146
VAR_NV6
F
N
R/W
User defined Network variable
293
805
1317
1829
2195
2451
147
VAR_NV7
F
N
R/W
User defined Network variable
295
807
1319
1831
2196
2452
148
VAR_NV8
F
N
R/W
User defined Network variable
297
809
1321
1833
2197
2453
149
VAR_NV9
F
N
R/W
User defined Network variable
299
811
1323
1835
2198
2454
150
VAR_NV10
F
N
R/W
User defined Network variable
301
813
1325
1837
2199
2455
151
VAR_NV11
F
N
R/W
User defined Network variable
303
815
1327
1839
2200
2456
152
VAR_NV12
F
N
R/W
User defined Network variable
305
817
1329
1841
2201
2457
153
VAR_NV13
F
N
R/W
User defined Network variable
307
819
1331
1843
2202
2458
154
VAR_NV14
F
N
R/W
User defined Network variable
309
821
1333
1845
2203
2459
155
VAR_NV15
F
N
R/W
User defined Network variable
311
823
1335
1847
2204
2460
156
VAR_NV16
F
N
R/W
User defined Network variable
313
825
1337
1849
2205
2461
157
VAR_NV17
F
N
R/W
User defined Network variable
315
827
1339
1851
2206
2462
158
VAR_NV18
F
N
R/W
User defined Network variable
317
829
1341
1853
2207
2463
159
VAR_NV19
F
N
R/W
User defined Network variable
319
831
1343
1855
2208
2464
160
VAR_NV20
F
N
R/W
User defined Network variable
321
833
1345
1857
2209
2465
161
VAR_NV21
F
N
R/W
User defined Network variable
323
835
1347
1859
2210
2466