Reference – Lenze E94P PositionServo Modbus User Manual
Page 32

32
P94MOD01C
Reference
Index
Name
Type
Format
EPM
Access
Description
Range
Unit
RAM
Registers
32bit
Integer
Access
4X
Register #
RAM
Register
32bit
Float
Access
4X
Register #
EPM
Reg Copy
32bit
Integer
Access
4X
Register #
EPM
Reg Copy
32bit
Float
Access
4X
Register #
RAM
Register
16bit
Signed
Integer
4X
Register #
EPM
INT16
4X
Register #
66
VAR_OUTPUT
W
N
R/W
Digital outputs states. Writing to this
variables sets/resets digital outputs except
outputs which have been assigned special
function.
Output 1 Bit 0
Output 2 Bit 1
Output 3 Bit 2
Output 4 Bit 3
Output 1 -
Output 4
133
645
1157
1669
2115
2371
67
VAR_IP_ADDRESS
W
Y
R/W
Ethernet IP address. IP address changes at
next boot up. 32 bit value
135
647
1159
1671
2116
2372
68
VAR_IP_MASK
W
Y
R/W
Ethernet IP NetMask. Mask changes at next
boot up. 32 bit value
137
649
1161
1673
2117
2373
69
VAR_IP_GATEWAY
W
Y
R/W
Ethernet Gateway IP address. Address
changes at next boot up. 32 bit value
139
651
1163
1675
2118
2374
70
VAR_IP_DHCP
W
Y
R/W
Use DHCP
0 - manual; 1 - use DHCP service
0 - 1
141
653
1165
1677
2119
2375
71
VAR_AIN1
F
N
R
Analog Input AIN1 current value
[V]olt
143
655
1167
1679
2120
2376
72
VAR_AIN2
F
N
R
Analog Input AIN2 current value
[V]olt
145
657
1169
1681
2121
2377
73
VAR_BUSVOLTAGE
F
N
R
Bus voltage
[V]olt
147
659
1171
1683
2122
2378
74
VAR_HTEMP
F
N
R
Heatsink temperature
0 - for temperatures < 40C and actual heat
sink temperature for temperatures >40 C
0 - actual
heat sink
temperature
[c]
149
661
1173
1685
2123
2379
75
VAR_ENABLE_
ACCELDECEL
vel
Y
R/W
Enable Accel/Decel function for velocity
mode
0 - disable; 1 - enable
0 - 1
151
663
1175
1687
2124
2380
76
VAR_ACCEL_LIMIT
vel
F
Y
R/W
Accel value for velocity mode
0.1 -
5000000
Rpm*Sec
153
665
1177
1689
2125
2381
77
VAR_DECEL_LIMIT
vel
F
Y
R/W
Decel value for velocity mode
0.1 -
5000000
Rpm*Sec
155
667
1179
1691
2126
2382
78
VAR_FAULT_RESET
W
Y
R/W
Reset fault configuration
0 - on activation of Enable/Inhibit input (A3)
1 - on deactivation of Enable/Inhibit input
(A3)
0 - 1
157
669
1181
1693
2127
2383
79
VAR_M2SRATIO_MASTER
W
Y
R/W
Master to system ratio
Master counts range: -32767 - +32767
-32767 -
+32767
159
671
1183
1695
2128
2384
80
VAR_M2SRATIO_SYSTEM
W
Y
R/W
Master to system ratio
System counts range: 1 - 32767
1 - 32767
161
673
1185
1697
2129
2385
81
VAR_S2PRATIO_SECOND
W
Y
R/W
Secondary encoder to prime encoder ratio
Second counts range: -32767 - +32767
-32767 -
+32767
163
675
1187
1699
2130
2386
82
VAR_S2PRATIO_PRIME
W
Y
R/W
Secondary encoder to prime encoder ratio
Prime counts range: 1 - 32767
1 - 32767
165
677
1189
1701
2131
2387
83
VAR_EXSTATUS
W
N
R
Extended status. Lower word copy of DSP
status flags.
167
679
1191
1703
2132
2388
84
VAR_HLS_MODE
W
Y
R/W
Hardware limit switches
0 - not used; 1 - stop and fault; 2 - fault
0 - 2
169
681
1193
1705
2133
2389
85
VAR_AOUT_FUNCTION
W
Y
R/W
Analog output function range: 0 - 8
0 - Not assigned
1 - Phase Current (RMS)
2 - Phase Current (Peak Value)
3 - Motor Velocity
4 - Phase Current R
5 - Phase Current S
6 - Phase Current T
7 - Iq current
8 - Id current
0 - 8
171
683
1195
1707
2134
2390
86
VAR_AOUT_VELSCALE
F
Y
R/W
Analog output scale for velocity quantities.
0 - 10
mV/Rpm
173
685
1197
1709
2135
2391
87
VAR_AOUT_CURSCALE
F
Y
R/W
Analog output scale for current related
quantities.
0 - 10
V/A
175
687
1199
1711
2136
2392
88
VAR_AOUT
F
N
W
Analog output value.(Used if VAR #85 is
set to 0)
0 - 10
V
177
689
1201
1713
2137
2393
89
VAR_AIN1_DEADBAND
F
Y
R/W
Analog input #1 dead-band. Applied when
used as current or velocity reference.
0 - 100
mV
179
691
1203
1715
2138
2394
90
VAR_AIN1_OFFSET
Y
R/W
Analog input #1 offset. Applied when used as
current/velocity reference
-10,000 to
+10,000
mV
181
693
1205
1717
2139
2395