NOTE:
In true Modbus, 3X and 4X Registers are numbered starting at 1. This is known as ‘one based’ addressing.
However, when transmitted to a slave over the serial link, the actual address transmitted is one less.
Some Modbus masters will allow for the first register number to be 0. This is known as ‘zero based’
addressing. If this is the case, the Modbus register numbers listed in this manual must be offset by -1 to
properly program a master using ‘zero-based’ addressing.
Index
Name
Type
Format
EPM
Access
Description
Range
Unit
RAM
Registers
32bit
Integer
Access
4X
Register #
RAM
Register
32bit
Float
Access
4X
Register #
EPM
Reg Copy
32bit
Integer
Access
4X
Register #
EPM
Reg Copy
32bit
Float
Access
4X
Register #
RAM
Register
16bit
Signed
Integer
4X
Register #
EPM
INT16
4X
Register #
1
VAR_IDSTRING
N
R
Drive’s identification string
3
515
1027
1539
2050
2306
2
VAR_NAME
Y
R/W
Drive’s symbolic name
5
517
1029
1541
2051
2307
3
VAR_SERIAL_NUMBER
R
Drive’s serial number
7
519
1031
1543
2052
2308
4
VAR_MEM_INDEX
R/W
Position in RAM file
(0 - 32767)
9
521
1033
1545
2053
2309
5
VAR_MEM_VALUE
R/W
Value to be read or written to the RAM file
11
523
1035
1547
2054
2310
6
VAR_MEM_INDEX_
INCREMENT
R/W
Holds value the MEM_INDEX will modify once
the R/W operation is complete
13
525
1037
1549
2055
2311
7
VAR_VELOCITY_ACTUAL
R
Actual measured motor velocity
NOTE: Only applicable to MVOB drives with
Firmware 4.00 and higher.
15
527
1039
1551
2056
2312
8
VAR_RSVD_2
17
529
1041
1553
2057
2313
9
VAR_DFAULT
R
Drive Default Settings
19
531
1043
1555
2058
2314
10
VAR_M_ID
mtr
Y
R/W*
Motor ID
21
533
1045
1557
2059
2315
11
VAR_M_MODEL
mtr
Y
R/W*
Motor model
23
535
1047
1559
2060
2316
12
VAR_M_VENDOR
mtr
Y
R/W*
Motor vendor
25
537
1049
1561
2061
2317
13
VAR_M_ESET
mtr
Y
R/W*
Motor Feedback Resolver: ‘Positive for CW’
0 - none
1 - Positive for CW
0 - 1
27
539
1051
1563
2062
2318
14
VAR_M_HALLCODE
mtr
Y
R/W*
Hallcode index
0 - 5
29
541
1053
1565
2063
2319
15
VAR_M_HOFFSET
mtr
Y
R/W*
Reserved
31
543
1055
1567
2064
2320
16
VAR_M_ZOFFSET
mtr
Y
R/W*
Resolver Offset
0 - 360
33
545
1057
1569
2065
2321
17
VAR_M_ICTRL
mtr
Y
R/W*
Reserved
35
547
1059
1571
2066
2322
18
VAR_M_JM
mtr
Y
R/W*
Motor moment of inertia Jm
0 - 0.1
Kgm2
37
549
1061
1573
2067
2323
19
VAR_M_KE
mtr
Y
R/W*
Motor voltage or back EMF constant Ke
1 - 500
V/Krpm
39
551
1063
1575
2068
2324
20
VAR_M_KT
mtr
Y
R/W*
Motor torque or force constant Kt
0.01 - 10
Nm/A
41
553
1065
1577
2069
2325
21
VAR_M_LS
mtr
Y
R/W*
Motor phase-to-phase inductance Lm
0.1 - 500
mH
43
555
1067
1579
2070
2326
22
VAR_M_RS
mtr
Y
R/W*
Motor phase-to-phase resistance Rm
0.01 - 500
[Ohm]
45
557
1069
1581
2071
2327
23
VAR_M_MAXCURRENT
mtr
Y
R/W*
Motor’s max current(RMS)
0.5 - 50
[A]mp
47
559
1071
1583
2072
2328
24
VAR_M_MAXVELOCITY
mtr
Y
R/W*
Motor’s max velocity
500 - 20000
RPM
49
561
1073
1585
2073
2329
25
VAR_M_NPOLES
mtr
Y
R/W*
Motor’s poles number
2 - 200
51
563
1075
1587
2074
2330
26
VAR_M_ENCODER
mtr
Y
R/W*
Encoder resolution
256 - 65536
* 12/Npoles
PPR
53
565
1077
1589
2075
2331
27
VAR_M_TERMVOLTAGE
mtr
Y
R/W*
Nominal Motor’s terminal voltage
50 - 800
[V]olt
55
567
1079
1591
2076
2332
28
VAR_M_FEEDBACK
mtr
Y
R/W*
Feedback type
1 - Encoder; 2 - Resolver
1 - 2
57
569
1081
1593
2077
2333
29
VAR_ENABLE_SWITCH_
TYPE
W
Y
R/W
Enable switch function
0 - inhibit only; 1 - Run
0 - 1
Bit
59
571
1083
1595
2078
2334
30
VAR_CURRENTLIMIT
F
Y
R/W
Current limit
[A]mp
61
573
1085
1597
2079
2335
31
VAR_
PEAKCURRENTLIMIT16
F
Y
R/W
Peak current limit for 16kHz operation
[A]mp
63
575
1087
1599
2080
2336
32
VAR_PEAKCURRENTLIMIT
F
Y
R/W
Peak current limit for 8kHz operation
[A]mp
65
577
1089
1601
2081
2337
33
VAR_PWMFREQUENCY
W
Y
R/W
PWM frequency selection
0 - 16kHz; 1 - 8kHz
0 - 1
67
579
1091
1603
2082
2338
* These are all R/W variables but they only become active after variable 247 is set.