Key for overview
Position
Description
0
9300 vector frequency inverter
Connections and interfaces
Position
Description
L1, L2, L3, PE Mains connection
+UG, −UG
DC supply (only for the variants V210, V240, V270, V300)
BR1, BR2
Connection of brake resistor (only for the variants V210, V240, V270, V300)
U, V, W, PE
Motor connection
X1
AIF interface (automation interface)
slot for communication module (e.g. keypad XT EMZ9371BC)
X3
Jumper for setting the analog input signal at X6/1, X6/2
X4
Terminal strip for connection of system bus (CAN)
X5
Terminal strips for connection of digital inputs and outputs
X6
Terminal strips for connection of analog inputs and outputs
X8
Sub−D connector (male) for connection of incremental encoder with TTL level or sin/cos encoder and KTY ther-
mal sensor of the motor
X9
Sub−D connector (male) for connection of digital frequency input signal
X10
Sub−D connector (female) for connection of digital frequency output signal
X11
Terminal strip for connection of relay output K
SR
for "safe standstill"
Status displays
Position
LED red
LED green
Operating status
Off
On
Controller is enabled
On
On
Mains is switched on and automatic start is inhibited
Off
Blinking slowly
Controller is inhibited
Off
On
Motor data identification is active
Blinking quickly
Off
Undervoltage or overvoltage
Blinking slowly
Off
Active fault