4 changing and saving parameters, Changing and saving parameters, Parameter setting – Lenze EVF9338−EV User Manual
Page 17
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
l
17
EDKVF93−04 EN 2.0
Function keys
)
Note!
Shortcuts with
T:
Press and hold
T, then press the second key in addition.
Key
Function
Menu level
Code level
Parameter level
Operating level
V
Change to the
parameter level
Change to the operating
level
Change to the code
level
T V
Go to the "Short setup"
menu and load
predefined
configurations
1)
Accept parameters
when SHPRG
p or
SHPRG is displayed
z
y
Change between menu
items
Change of code number
Change of digit via
cursor
T z
T y
Quick change between
menu items
Quick change of code
number
Quick change of digit
via cursor
Z
Change between main menu, submenu and code
level
Cursor to the right
Y
Cursor to the left
U
Deactivate the function of the key
S, the LED in the key goes off
S
Inhibit the controller, the LED in the key is lit.
Reset fault (TRIP−Reset): 1. Remove the cause of malfunction
2. Press
S
3. Press
U
1)
Only active for operation with standard devices of the 8200 vector or 8200 motec series
3.1.4
Changing and saving parameters
)
Note!
Your settings have an effect on the current parameters in the main memory.
You must save your settings in a parameter set so that they are not lost when
the mains are connected.
If you only need one parameter set, save your settings as parameter set 1,
since parameter set 1 is loaded automatically after mains connection.
Step
Key
sequence
Action
1.
Select the menu
z y Z Y
Use the arrow keys to select the desired menu
2.
Change to the code level
Z
Display of the first code in the menu
3.
Select code or subcode
y z
Display of the current parameter value
4.
Change to the parameter level
V
5.
When SHPRG is displayed, inhibit the
controller
S
1)
The drive coasts
6.
Change parameter
A
Z Y
Move cursor below the digit to be changed
B
y z
Change of digit
T y
T z
Quick change of digit
7.
Accept the changed parameter