Technical data
General data and operating conditions
2
2.1
l
8
EDSTCXX EN 2.0
2
Technical data
2.1
General data and operating conditions
Type
ETCHx
ETCPx
Labelling and approval
CE (compliance with the EMC Directive)
Climatic conditions
Storage
1 K3 per IEC/EN 60721−3−2
Temperature
−20 °C ... +60 °C;
D
max
= 20 K/h
Transport
2 K3 per IEC/EN 60721−3−2
Temperature
−20 °C ... +60 °C;
D
max
= 20 K/h
Operation
1)
3 K3 per IEC/EN 60721−3−2
Temperature
−0 °C ... +50 °C;
D
max
= 10 K/h
above 1000 m site altitude permissible temperature reduced by 1 K/300 m
Atmospheric pressure
860 hPa to 1060 hPa
Rel. humidity
8 % ... 80 % (non condensing)
Vibration resistance
Shock (10 ms)
max. 5 G
Vibration (5 ... 100 Hz)
max. 0.5 G
Noise immunity
EN50082−1 = severity 3
Noise emission
EN50082−2 = limit value B
Packaging
Dustproof packaging
Protection category
IP20
IP00
Installation position
vertical
−
Installation clearances
top and bottom 80 mm
−
1)
At maximum load, vertical installation and sufficient convection