6 analogue module, Analogue module, Technical data – Lenze ETCxxxxx User Manual
Page 13
Technical data
Rated data
Analogue module
2.2
2.2.6
l
13
EDSTCXX EN 2.0
2.2.6
Analogue module
Type
ETCHA022
Use
2 channel analogue input/output module, 0 V or −10 V ... +10 V
Weight
125 g
Dimensions (H x W x D)
99 x 22.5 x 114.5 mm
Supply voltages:
Control voltage (sensor feed)
typ. 24 V DC (18 ... 32 V DC) feed via ME bus
Logical voltage
typ. 24 V DC (18 ... 32 V DC) feed via ME bus
Power loss
max. 6.2 W
Input:
Input impedance
> 500 kOhm
Measuring range
(switchable)
0 ... 10 V or –10 V ... +10 V
Voltage at the input
max. 32 V
Resolution
12 Bit
Conversion method
successive approximation
Value of the LSB
2.5 mV for measuring range 0 ... 10 V or
5 mV for measuring range −10 V ... +10 V
Inaccuracy
max. 50 mV for measuring range 0 ... 10 V or max. 100 mV for measuring range −10 V ... +10 V
Scanning frequency
205 Hz
Filters
analogue low−pass filter of 1st degree with a limiting frequency of 30 Hz, digital configurable
low−pass filter
Permitted sensor types
Active and passive sensors
Sensor feed, sensor current
10 V regulated, max. 10 mA
Permitted connection cables
Shielded cables; shield placed before the module
Output:
Output range (switchable)
0 ... 10 V or −10 ... +10 V
max. 0 ... 10.238 V or −10.238 V ... +10.238 V
Output current
max. 2 mA
Min. load
5 kOhm
Resolution
12 Bit
Value of the LSB
2.5 mV or 5 mV
Inaccuracy
max. 50 mV or 100 mV
Output rate
min. 10 ms continually, min. 5 ms continually (digital input filter switched off)
Filters
analogue low−pass filter of 1st degree with a limiting frequency of approx. 730 Hz
Permitted connection cables
Shielded cables, shield placed before the module
Power recovery
max.
±
32 V at an input/output terminal
Potential isolation
500 V DC between ME bus and input/output terminals
Fuse:
Logic component
SMD time−lag fuse 500 mA
System voltage
SMD time−lag fuse 1500 mA
Protection
l
24 V system voltage is protected by a definite plug−in direction in the housing.
l
5 V bus voltage is protected by a definite plug−in direction in the housing.
l
Sensor supply is protected against short circuit, overcurrent and negative feed
l
Current and voltage inputs (optional) are protected against voltages up to 32 V
l
Input protection via high resistance voltage dividers
l
Protection of the sensor feed via series diodes and active current limitation
l
ESD protection via Transil diodes at PE
l
Output protection via passive current limitation
l
Series and parallel diodes, short−circuit proof
l
ESD protection via Transil diodes at PE