3 appendix, 1 code table, 1 l_brk – Lenze DDS Function library 9300 Servo User Manual
Page 27: 2 l_mfail, Code table, L_brk, L_mfail, Function block library lenze9300servo.lib, 3appendix, Appendix

Function block library Lenze9300Servo.lib
Appendix
3−1
L
Lenze9300Servo.lib EN 1.1
3
Appendix
3.1
Code table
How to read the code table:
Column
Abbreviation
Meaning
Code
C0039
1
2
…
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
…
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0156]
Parameter value of the code can only be modified when the controller is inhibited
LCD
Keypad LCD
·
DIS: ...
display only
·
all others are parameter values
Lenze
Factory setting of the code
*
The column "Important" contains further information
Choice
1 {1
%} 99 Minimum value
{smallest step/unit}
maximum value
IMPORTAN
T
−
Additional, important explanation of the code
3.1.1
L_BRK
FB description:
(
Code
LCD
Possible settings
IMPORTANT
Lenze
Choice
C0195 wActivationTime
99.9
0.0 {0.1
s}
99.9
99.9 s
infinite
Brake closing time of L_BRK1
·
Engaging time of the mechanical holding
brake (see technical data of the brake).
·
After the time under C0195 has elapsed,
the status "mechanical brake closed" is
reached
C0196 wReleaseTime
0.0
0.0 {0.1
s}
60.0 Brake opening time of L_BRK1
·
Disengaging time of the mechanical
holding brake (see technical data of the
brake).
·
After the time under C0196 has elapsed,
the status "mechanical brake opened" is
reached
C0244 nMSet
0.00
−100.00 {0.01
%} 100.00
100 % = value of C0057
Holding moment of the DC−brake of L_BRK1
3.1.2
L_MFAIL
FB description:
(
Code
LCD
Possible settings
IMPORTANT
Lenze
Choice
C0980 nVp
0.500
0.001 {0.001}
31.000 Gain Vp of L_MFAIL1
C0981 nTn
100
20 {1
msec}
2000 Time constant of L_MFAIL1
C0982 nTir
2.000
0.001 {0.001
sec}
16.000 Acceleration time Tir of L_MFAIL1
C0983 wRetriggerTime
1.000
0.001 {0.001
sec}
60.000 Retrigger time of L_MFAIL1