Electrical installation – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual
Page 125

Electrical installation
Mains connection
Fuses and cable cross−sections according to UL
l
125
EDK82EV222 DE/EN/FR 13.0
Rated fuse current / cable cross−section
8200 vector
Circuit−breaker
Fuse
8200 vector
L1, L2, L3, N, PE
Type
L1, L2, L3, N, PE
Type
[AWG]
[A]
[AWG]
[A]
Type
Mains 1/N/PE AC 230/240 V − operation with mains choke/mains filter
E82xV251K2C
10
16
15
14 4)
E82xV371K2C
10
16
15
14 4)
E82xV551K2C
10
16
15
14 4)
E82xV751K2C
15
14
15
14 4)
E82xV152K2C
20
2 x 16
25
2 x 14 4)
E82xV222K2C
20
2 x 16
30
2 x 14 4)
Mains 3/PE AC 230/240 V − operation without mains choke/mains filter
E82xV551K2C
6
18
15
14 4)
E82xV751K2C
10
16
15
14 4)
E82xV152K2C
15
14
15
14 4)
E82xV222K2C
15
2 x 16
20
2 x 14 4)
Mains 3/PE AC 230/240 V − operation with mains choke/mains filter
E82xV551K2C
6
18
15
14 4)
E82xV751K2C
10
16
15
14 4)
E82xV152K2C
15
14
15
14 4)
E82xV222K2C
15
2 x 16
20
2 x 14 4)
Mains 3/PE AC 400/500 V − operation without mains choke/mains filter
E82xV551K4C
6
18
15
14 4)
E82xV751K4C
6
18
15
14 4)
E82xV152K4C
10
16
15
14 4)
E82xV222K4C
10
16
15
14 4)
Mains 3/PE AC 400/500 V − operation with mains choke/mains filter
E82xV551K4C
6
18
15
14 4)
E82xV751K4C
6
18
15
14 4)
E82xV152K4C
10
16
15
14 4)
E82xV222K4C
10
16
15
14 4)
4)
Pin−end connector required