2 storage, Storage, Mechanical installation – Lenze GSS User Manual
Page 28
Mechanical installation
Storage
l
28
BA 12.0023−EN 7.0
5.2
Storage
If you do not install the gearbox immediately, ensure appropriate conditions of storage.
ƒ
Generally
– Store gearbox in dry, clean (dust−free) and sunlight−protected indoor rooms.
– The storage location must be free of vibration and shocks (V
eff
< 0.2 mm/s) to
avoid roller bearing downtime damage.
– Temperature changes with condensate formation must be avoided.
– Do not activate breather element to prevent air exchange with ambient air.
ƒ
Up to one year:
– Store the gearbox with breather such that the breather screw is located at the top.
– Shafts and bright surfaces are delivered with protection against corrosion. Spots
with defective corrosion protection must be re−treated.
– On motors with condensation drain holes (option), the plug screw must be
ƒ
Over one year, up to two years:
– Before storage, shafts and bright surfaces must be provided with a long−term
anticorrosive agent (e.g. Anticorit BW 366 from the company Fuchs).
– Set up gearbox in mounting position A.
– Fill gearbox with oil grade filled in (see nameplate) up to the top breather / oil
bore. Then mount plug screw or breather element (do not activate) again.