4 technical data, 1 general data and operating conditions, Technical data – Lenze GSS User Manual
Page 25: General data and operating conditions, 4technical data

Technical data
General data and operating conditions
4
l
25
BA 12.0023−EN 7.0
4
Technical data
4.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
Approvals
M
File No. E210321
CCC
Protection of persons and equipment
Degree of protection
IEC/EN 60034−5
See nameplate
Degrees of protection only apply to horizontal installation
All unused plug−in connections must be sealed with
protective caps or dummy connectors.
Thermal class
F (155 °C)
IEC/EN 60034−1
Exceedance of the temperature limit weakens or destroys the
insulation
Permissible voltage
According to limiting curve A of the pulse voltage from
IEC / TS 60034−25 (image 14)
EMC
Noise emission
IEC/EN 61800−3
Depending on the controller, see documentation for the
controller.
Noise immunity
Operating conditions
Ambient conditions
Climatic
Transport
IEC/EN 60721−3−2
2K3 (−20 ... +70 °C)
Storage
IEC/EN 60721−3−1
1K3 (−20 ... +60 °C)
< 3 months
1K3 (−20 ... +40 °C)
> 3 months
Operation
IEC/EN 60721−3−3
Without brake −15 °C ... +40 °C
With brake −10 °C ... +40 °C
Without power reduction
> +40 °C
With power reduction see,
catalogue
Site altitude
< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue
Humidity
Average relative humidity 85 %, without condensation
Electrical
Motor connection dependent on the
controller
See inverter instructions
Length of motor cable
Length of cable for speed feedback
Mechanical
IEC/EN60721−3−3
3M6