1 temperatures, 2 ambient conditions, Temperatures – Lenze GSS User Manual
Page 14: Ambient conditions, Safety instructions
Safety instructions
Residual hazards
Temperatures
l
14
BA 12.0023−EN 7.0
2.4.1
Temperatures
The permissible temperature range is determined by the following:
ƒ
The lubricant specifications in connection with the expected oil temperatures in
operation (see chapter 8.1 and nameplate).
ƒ
The thermal class of the motor considering the motor temperature expected during
operation (see nameplate and/or Operating Instructions of the motor).
The operating temperature is determined by the power loss, the ambient temperature and
the cooling system!
(
Stop!
With mineral oil, the upper temperature limit for continuous operation is 80°C,
with synthetic oil and shaft sealing rings made of FP (Viton) 100°C. If these
temperatures are exceeded, measures are necessary to reduce the
temperature, see chapter 9.
}
Danger!
Depending on the operating conditions, surfaces may be hot, provide
protection against accidental contact.
2.4.2
Ambient conditions
ƒ
Gearboxes are protected against dust and spray water.
ƒ
Motors according to their enclosure (see nameplate and/or Operating Instructions
for the motor).
ƒ
Ambient media − especially chemically aggressive − can destroy shaft seals and
coatings (plastic). Abrasive media endanger shaft seals.
ƒ
The installation site of the drive must be free of shocks and vibration.
ƒ
Dirt of dust deposits impede the heat dissipation (cooling).