Parameter reference
Parameters relevant for AS-i communication
67
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13900
C13901
C13902
C13950
Parameter | Name:
C13900 | Firmware product type
Data type: VISIBLE_STRING
Index: 10675 = 0x29B3
Display of the product type (string with a length of 8 bytes)
• The following identification code is displayed: "E84DGFCA".
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 10674 = 0x29B2
Display of the compilation date of the firmware (string with a length of 20 bytes)
• The date ("MMM DD YYYY") and time ("hh:mm:ss") are output, e.g. "Mar 21 2005 12:31:21".
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673 = 0x29B1
Display of the firmware version (string with a length of 5 bytes)
• An identification code is displayed, e.g. "00.80".
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13950 | Internal communication status
Data type: UNSIGNED_8
Index: 10625 = 0x2981
Display of the internal status of the communication unit
Selection list
(read only)
Info
0 Module not initialised
1 Module ready for initialisation
2 Reading module parameters
3 Module parameters have been read
4 Initialisation of external protocol
5 Online
6 Module timeout
7 'Stay Alive' condition
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT