3 mechanical installation, 1 important notes, Mechanical installation – Lenze EZS3-xxxA200 Sinusoidal filter 180-480A User Manual
Page 26: Important notes

Mechanical installation
Important notes
3
l
26
EDKZS3−480A200 DE/EN/FR/ES/IT 1.0
3
Mechanical installation
3.1
Important notes
ƒ
The mounting location must always fulfill the operating conditions
specified in the Technical data. (
¶ 24). If necessary, take additional
measures.
ƒ
The mounting plate of the control cabinet must be:
–
electrically conductive
–
free of lacquer
ƒ
The mechanical connections must always be ensured.
(
Stop!
Heavy device weight
The device is very heavy and must be lifted for the mounting.
Possible consequences:
ƒ
Injury to persons, particularly backache when lifting and holding
the device, respectively
ƒ
Injury to persons and damage to material assets due to the
device falling down
Protective measures:
ƒ
The device must only be carried with a load bearing system such
as an indoor crane permitted for the device weight
ƒ
Before the transport, the hoist, the load bearing system and
lifting accessories must be checked for sufficient payload and
faultless status
ƒ
Do not remove the hoist and the lifting accessories until the
device lies safe on a stable surface or is finally mounted.