Controls and displays, Operation – Lenze MP 9000 DVI Operating Instructions User Manual
Page 33
![background image](/manuals/565648/33/background.png)
Operation
Controls and displays
Monitor Panel MP 800 DVI / MP 1000 DVI / MP 1000s DVI / MP 2000 DVI /
l
33
BA_MP9000DVI DE 4.0
7.2
Controls and displays
7.2.1
Monitor Panel MP 800 DVI / MP 1000 DVI / MP 1000s DVI / MP 2000 DVI /
MP 5000 DVI / MP 9000 DVI
-
F3
Fail
Power
F1
+
F2
Status
1
2
0
CS50x0−022
Pos. Designation
Function
Standard mode
Service mode
Switch on mode:
Press "
[" for 4 s
Switch off mode:
Press "
[" or wait for 35 s
0 Display
Application−dependent
1 Status LEDs
Power (green):
l
Is ON when the supply voltage is present.
Fail (red):
l
Is On when a power supply failure has occurred.
l
Is blinking when the screen signal is missing.
Status (yellow):
l
Application−dependent
2 Function keys
F1 ... F3: Send key code for Shift−F1 ...
Shift−F3
Tool: Application−dependent
+: Increase screen brightness
−: Reduce screen brightness